Alde • Alde Flow

Alde Flow

Official technical documentation and workshop diagnostics for Flow.

Technical Specifications

Operating Voltage12V DC
Power Consumption0.3A
Gas Or PressureMax pump pressure domestic water: 0.22 MPa (2.2 bar) / Max radiator water pressure: 0.05 MPa (0.5 bar)
Fuse Ratings3.15A
Dimensions CutoutWidth 225 mm, Length 320 mm, Height 180 mm

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
N/A
No central heating after a period of time
Possible Cause: Incorrect non-return valve orientation
Check that the direction of the non-return valves is correct.DIY Safe
N/A
No continuous hot water
Possible Cause: Hot Water Boost automatically deactivates after 30 minutes
Activate Hot Water Boost again.DIY Safe
N/A
No continuous hot water
Possible Cause: 'Aux Hot Water Tank' is not selected in installed accessories
Check that 'Aux Hot Water Tank' is ticked in Installed Accessories Menu.DIY Safe
N/A
No continuous hot water
Possible Cause: Air trapped in the system
Bleed the system of air.DIY Safe
N/A
No continuous hot water
Possible Cause: Circulation pump not connected properly to options dongle
Check that the 12 V circulation pump is connected to the options dongle correctly.DIY Safe
N/A
No continuous hot water
Possible Cause: Gas and electric heating not both selected or functioning
Check that both gas and electric heating are selected and functioning.DIY Safe
N/A
No continuous hot water
Possible Cause: Circulation pump lacks power or is malfunctioning
Check that the 12 V circulation pump has 12 V power and is functioning.DIY Safe
N/A
'Aux Hot Water Tank' does not appear in Installed Accessories Menu
Possible Cause: Options dongle is not properly connected to the boiler
Check that the options dongle is connected to the Compact HE boiler.DIY Safe
N/A
'Aux Hot Water Tank' does not appear in Installed Accessories Menu
Possible Cause: Power supply needs a reset to clear saved behaviours after connection
Reset the 12 V power supply to the boiler after connecting the options dongle to clear saved behaviours.DIY Safe
N/A
Noise from 12 V circulation pump
Possible Cause: Air trapped in the system
Bleed the system of air.DIY Safe
N/A
There comes no water despite the fact that the tap is open
Possible Cause: Vehicle fresh water pump is turned off or not working
Check that the vehicle's fresh water pump is on.DIY Safe
N/A
There comes no water despite the fact that the tap is open
Possible Cause: Ice plugs present in the water tank or pipes
Check that there are no ice plugs in water tank or pipes.DIY Safe
N/A
There comes no water despite the fact that the tap is open
Possible Cause: Draining valves or FrostControl are open
Check that all draining valves / FrostControl are closed.DIY Safe
N/A
No warm water from the outlet when the tap is opened
Possible Cause: Water pump malfunctioning or lack of water supply in tank
Check that the vehicle's water pump is functioning and there is a supply of water.DIY Safe
N/A
The 'Aux Hot Water Tank' symbol flashes
Possible Cause: Water is currently in the process of being heated
Wait for the heating cycle to finish. The symbol changes to being permanently lit when the temperature reaches 60°C.DIY Safe