Alde • Other

Alde Sensor for cylinder changeover – Defroster (EisEx)

Official technical documentation and workshop diagnostics for Sensor for cylinder changeover – Defroster (EisEx).

Technical Specifications

Operating Voltage12 V DC
Power ConsumptionSummer operation: 0 mA, Winter operation with defroster: 160 mA, Winter operation without defroster: 0 mA
Fuse Ratings1A inline for red cable

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
N/A
Control panel does not indicate whether the LP gas cylinder is full or empty, and defroster does not warm up the cylinder changeover.
Possible Cause: Main switch on the control panel is set to "Off".
Switch the main switch on the control panel to "On".DIY Safe
N/A
Defroster does not warm up the cylinder changeover during winter conditions.
Possible Cause: Summer function is selected instead of winter function, or incorrect polarity on 12V supply lines.
Select the Winter function on the control panel. If incorrect polarity is suspected, check the 12V supply connections ensuring red is connected to positive (+) and black to negative (-). If faults persist, contact an authorised service agent.DIY Check / Tech Fallback
N/A
Defroster fails to operate or electrical system shows faults after installation in the cylinder box.
Possible Cause: Electrical connections or cable extensions carried out incorrectly inside the LP gas compartment, or damaged cables.
Disconnect power supply, inspect external wiring routed outside the cylinder box, and ensure proper fusing. Have repairs and internal cylinder box electrical connections carried out by a specialist.DIY Check / Tech Fallback