Alde Voice Control 3020180
Official technical documentation and workshop diagnostics for Alde Voice Control.
Technical Specifications
Operating Voltage5V DC or 12V DC
Power ConsumptionGateway: 110 mA (active/standby); Microphone: 200 mA (active), 180 mA (standby)
Fuse Ratings1A inline
Dimensions CutoutGateway: 56 x 27 x 108 mm; Microphone: h 15 mm, Ø 64 mm
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|
N/A | Nothing happens on the Alde control panel when giving a voice command. Possible Cause: Microphone did not receive the wake-up phrase, pairing error, communication issue, or invalid command. | Check if the microphone lights up red. If not, repeat the phrase with a different intonation or volume. If yes, check gateway LEDs and cabling. Ensure the command is supported by your panel version. If unresolved, contact your dealer. | DIY Check / Tech Fallback |
N/A | Problem on pairing the Gateway with the microphone. Possible Cause: Corrupted pairing memory in the gateway or microphone. | Clear the memory by speaking the voice command 'Alde listen, uninstall microphone', hold the pairing button on the gateway for at least 10 seconds, then re-initiate pairing. | DIY Safe |
N/A | Gateway LED flashes red (1 second on, 1 second off). Possible Cause: Serious fault indicating that contact with Alde Voice Control is broken. | Contact an authorised service agent. | Professional Intervention Required |
N/A | Gateway shows a steady red light. Possible Cause: System upgrade is not working correctly on the Alde control panel. | Contact an authorised service agent. | Professional Intervention Required |