Alde • Alde Voice Control

Alde Voice Control 3020180

Official technical documentation and workshop diagnostics for Alde Voice Control.

Technical Specifications

Operating Voltage5V DC or 12V DC
Power ConsumptionGateway: 110 mA (active/standby); Microphone: 200 mA (active), 180 mA (standby)
Fuse Ratings1A inline
Dimensions CutoutGateway: 56 x 27 x 108 mm; Microphone: h 15 mm, Ø 64 mm

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
N/A
Nothing happens on the Alde control panel when giving a voice command.
Possible Cause: Microphone did not receive the wake-up phrase, pairing error, communication issue, or invalid command.
Check if the microphone lights up red. If not, repeat the phrase with a different intonation or volume. If yes, check gateway LEDs and cabling. Ensure the command is supported by your panel version. If unresolved, contact your dealer.DIY Check / Tech Fallback
N/A
Problem on pairing the Gateway with the microphone.
Possible Cause: Corrupted pairing memory in the gateway or microphone.
Clear the memory by speaking the voice command 'Alde listen, uninstall microphone', hold the pairing button on the gateway for at least 10 seconds, then re-initiate pairing.DIY Safe
N/A
Gateway LED flashes red (1 second on, 1 second off).
Possible Cause: Serious fault indicating that contact with Alde Voice Control is broken.
Contact an authorised service agent.Professional Intervention Required
N/A
Gateway shows a steady red light.
Possible Cause: System upgrade is not working correctly on the Alde control panel.
Contact an authorised service agent.Professional Intervention Required