Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
Batt Low - Illuminated
Main battery is below 10.5 volts
Possible Cause: Discharged battery, insufficient battery connection, or failed supply fuse
Check the battery charge level and connections, check the supply fuse, and if the problem persists, contact Truma Service.DIY Check / Tech Fallback
MPP - illuminated
CC charging
Normal operation indicating charging is in progress.DIY Safe
MPP - short flashing
CC ready to charge
Normal operation indicating the system is ready to charge.DIY Safe
>80% - illuminated
Main battery is almost fully charged
Normal operation indicating the battery is nearing full charge.DIY Safe
>80% flashing 1 pulse/sec
CC overheated
Possible Cause: Charge Controller is overheating
Allow the unit to cool down. If the problem persists, contact Truma Service.Professional Intervention Required
>80% flashing 2 pulse/sec
Main battery or solar panel over voltage
Possible Cause: Excessive voltage from battery or solar panel
Check the solar panel and battery voltage levels. If the problem persists, contact Truma Service.DIY Check / Tech Fallback
Batt Full - illuminated
Battery is fully charged
Normal operation indicating the battery has reached full charge.DIY Safe
All LED's flashing
Battery selection is incorrect
Possible Cause: Incorrect DIP switch configuration for the battery type
Check the battery type DIP switches on the bottom face of the charge controller and set them to match the correct battery type. If this does not solve the problem, contact Truma Service.DIY Check / Tech Fallback