Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|
2 yellow LED flashes | Battery charger over-temperature alarm | The alarm resets itself when the battery charger cools down. Check ventilation. | DIY Safe |
3 yellow LED flashes | Unsuitable battery voltage alarm | Use only 12V batteries. | DIY Safe |
4 yellow LED flashes | Unsuitable mains voltage alarm | Check that the mains voltage is within the range of 187–264V . If the alarm reoccurs, consult technical support. | DIY Check / Tech Fallback |
5 yellow LED flashes | Battery charge alarm defective | The alarm resets by disconnecting the power supply. If it reoccurs, consult technical support. | DIY Check / Tech Fallback |
6 yellow LED flashes | Battery over-temperature alarm (t > 50°C) Possible Cause: Battery temperature > 50°C | Charging is momentarily interrupted and the alarm self-resets when the battery cools down. Check the ventilation of the battery compartment or the state of the battery. | DIY Safe |
8 yellow LED flashes | Short circuit alarm | The alarm self-resets when the output short circuit is eliminated. | DIY Safe |