CBE BDS200
Official technical documentation and workshop diagnostics for BDS200.
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|
Operational Fault | Faulty battery Possible Cause: The battery has a shorted element or has completely exhausted its capacity. | The device isolates the damaged battery and signals the anomaly with long blinks on the corresponding LED on the BDS200 and the MC-180 control panel. To reset the device, reduce the connected loads and turn the BDS200 back on using the 3-position switch ref. 1. | DIY Safe |
Operational Fault | Overcurrent protection triggered Possible Cause: A current draw greater than 120A was detected on one of the two channels. | The overcurrent protection automatically opens the relay contact, disconnecting the connected battery. The batteries can be reset manually by turning the device off and on again. | DIY Safe |
Operational Fault | Battery protection function activated Possible Cause: The battery voltage dropped below 9.5V. | The battery protection function disconnects all users when the voltage drops below 9.5V to avoid irreversible damage. If the voltage drops below 8.5V, the device turns off automatically. To restore the device, reduce the connected loads and turn the BDS200 back on using the 3-position switch ref. 1. | DIY Safe |