CBE PC180-ST
Official technical documentation and workshop diagnostics for PC180-ST.
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|
Symbol ref. 9 blinking | Car battery (B1) alarm Possible Cause: Car battery voltage is lower than 12V | When car battery voltage is lower than 12V, car battery alarm is automatically activated together with symbol ref. 9 blinking. | DIY Safe |
Symbol ref. 10 blinking | Leisure battery alarm (B2) Possible Cause: Leisure battery voltage is lower than 11V | When leisure battery voltage is lower than 11V, leisure battery alarm is automatically activated together with symbol ref. 10 blinking. | DIY Safe |
LED flashing | Battery low / low voltage device intervention Possible Cause: Leisure battery reaches the minimal voltage level of 10V | An electronic device switches all the 12V mains off, when the leisure battery reaches the minimal voltage level of 10V. It is possible to switch on again all the mains for 1 minute by pressing the ON/OFF button. | DIY Safe |
Symbol ref. 11 blinking | Fresh water tank empty alarm Possible Cause: Fresh water tank is empty | If this symbol blinks the fresh water tank is empty. | DIY Safe |
Symbol ref. 12 blinking | Waste water tank full alarm Possible Cause: Waste water tank is full | If this symbol blinks the waste water tank is full. | DIY Safe |