Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|
Symbol 3 blinking | Car battery alarm (B1) Possible Cause: When the battery reaches a voltage lower than 12V | The alarm goes off when the voltage gets over 12.5V. | DIY Safe |
Operational Fault | Leisure battery discharge alarm (B2) Possible Cause: When leisure battery voltage gets 10.5V | Alarms go off when the voltage gets over 12.5V. | DIY Safe |
Symbol 12 | Minimum voltage control (battery protection) / electronic battery protection cuts off 12V users Possible Cause: When leisure battery reaches 10V (or control panel turns off automatically with a voltage lower than 9.5V) | It is possible to reactivate all users for one minute by pressing the on/off button on the control panel. Users are automatically reactivated when voltage is bigger than 13.5V. | DIY Safe |
Symbol 10 blinking | Fresh water tank alarm Possible Cause: Alarm turns on when fresh water level is lower than 10% of the tank capacity | It automatically turns off when level exceeds 20%. | DIY Safe |