Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
Symbol 3 blinking
Car battery alarm
Possible Cause: Car battery voltage gets under 12V
Alarm goes off when the voltage gets over 12.5V.DIY Safe
Operational Fault
Leisure battery discharge alarm
Possible Cause: Leisure battery voltage gets 10.5V
Alarms go off when the voltage gets over 12.5V.DIY Safe
Operational Fault
Leisure battery reserve alarm
Possible Cause: Leisure battery voltage gets 11.5V
Alarms are disactivated with voltage superior to 12.5V.DIY Safe
Symbol 12
Minimum voltage control (battery protection) activated
Possible Cause: Electronic battery protection device cuts off 12V users when leisure battery reaches 10V
It is possible to reactivate all users for one minute by pressing the on/off button on control panel. Users are automatically reactivated when voltage is bigger than 13.5V. Control panel automatically turns off with a voltage lower than 9.5V.DIY Safe
Operational Fault
Fresh water tank alarm
Possible Cause: Fresh water level is lower than 10% of the tank capacity
Alarm automatically turns off when level exceeds 20%.DIY Safe