Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|
Symbol ref. 16 blinking | Car battery discharge alarm Possible Cause: Car battery voltage goes below 12V | The alarm goes off when the voltage goes above 12.5V. | DIY Safe |
Operational Fault | Leisure battery reserve alarm Possible Cause: Leisure battery voltage reaches 11.5V | The alarms go off when the voltage goes above 12.5V. | DIY Safe |
Operational Fault | Leisure battery discharge alarm Possible Cause: Leisure battery voltage reaches 10.5V | The alarms go off when the voltage goes above 12.5V. | DIY Safe |
Symbol ref. 15 | Minimum voltage control (battery protection) device on Possible Cause: Leisure battery reaches 10V (or control panel turns off automatically with voltage lower than 9.5V) | The electronic battery protection device disconnects the 12V users. It is possible to connect all users for one more minute by pressing the on/off button. Users are automatically reconnected with a voltage higher than 13.5V. | DIY Safe |
Operational Fault | Fresh water tank alarm Possible Cause: Fresh water level goes below 1% of the tank capacity | Automatically turns off when level exceeds 2%. | DIY Safe |
Operational Fault | Waste water tank alarm Possible Cause: Waste water level exceeds the screw sensor level | To reset alarm press any test button. | DIY Safe |