CBE PL50-ST
Official technical documentation and workshop diagnostics for PL50-ST.
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|
Symbol ref. 17 | Car battery (B1) has run down Possible Cause: Car battery voltage goes below 12V | The alarm goes off when the voltage goes above 12.5V. | DIY Safe |
Symbol ref. 18 | Leisure battery (B2) reserve Possible Cause: Leisure battery voltage reaches 11.5V | Alarm goes off when the voltage goes above 12.5V. | DIY Safe |
Symbol ref. 18 | Leisure battery (B2) discharge Possible Cause: Leisure battery voltage reaches 10.5V | Alarm goes off when the voltage goes above 12.5V. | DIY Safe |
Symbol ref. 21 | Minimum voltage device active (Battery protection) Possible Cause: Leisure battery reaches the preset low voltage threshold | The electronic battery protection device disconnects the 12V users when leisure battery reaches the preset threshold and disables: pump, lights, awning light, 'AUX' and 'RH' output and 12V sockets. Users are automatically reconnected with a voltage higher than 13.5V. It is possible to connect all users for one more minute by pressing the on/off button on the control panel. | DIY Safe |
Symbol ref. 19 | Fresh or auxiliary water tank is empty Possible Cause: Fresh water level goes below 10% of the tank capacity | Alarm automatically turns off when level exceeds 20%. | DIY Safe |
Symbol ref. 20 (blinking) | Waste or auxiliary water tank is full Possible Cause: Waste water level exceeds 90% of the tank capacity | Alarm automatically turns off when level goes below 80%. | DIY Safe |
Symbol 'PUMP BLOCK' | Pump block is active Possible Cause: Water pump ran continuously for the pre-set non-stop service time | An electronic device automatically locks the water pump after a pre-set non-stop service time. | DIY Safe |
Red LED under fuse | Broken fuse alarm Possible Cause: A fuse is broken | Before replacing the fuse find the problem that determined the system to intervene and in case, have it fixed by relying on expert technicians. Replace with another fuse with the same value. | DIY Check / Tech Fallback |