Coachman • Caravan Owner's Handbook

Coachman Owner's Handbook (2026)

Official technical documentation and workshop diagnostics for Coachman Owner's Handbook (2026).

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
Green flashing
ATC active but self-test incomplete
Possible Cause: Self test incomplete
Drive forward to detect movement to complete self test and re check LEDDIY Safe
Red
ATC inactive
Remove 13 pin plug and wait 5 seconds. Reconnect plugDIY Safe
Red flashing
ATC has detected a fault
Remove 13 pin plug and wait 5 seconds. Reconnect the plug. If faulty and cannot be driven, remove push-rod as shown in the AL-KO handbook and consult AL-KO.DIY Check / Tech Fallback
LED not working
ATC has no power or LED faulty
Check push rod position as detailed in the AL-KO handbook before continuing your journey. Remove 13 pin plug and wait 5 seconds. Reconnect the plug. Check for constant live.DIY Safe
N/A
Pump fails to turn on
Possible Cause: Loose wiring connection, pump circuit has no power, blown fuse, pressure switch failure, defective motor, or float switches fail to operate.
Remake a sound connection. Replace fuse/reset. Reset pressure switch using manufacturer's instructions. Replace pump. Contact Whale Support.DIY Check / Tech Fallback
N/A
Tank leaking from drain plug
Possible Cause: Drain stem not engaged past O-ring.
Reseal ensuring the drain system is fully home.DIY Safe
N/A
Alde system is completely dead, control peak is blank
Check the 20 mm T3.15 Amp glass fuse in the boiler located under the lid of the black plastic service hatch, in a green plastic fuse holder. Check the 12V supply to the boiler, it should be above 12V. Check the 12V cable is plugged into the boiler and control panel.DIY Safe
N/A
Alde panel failure 1 & panel failure 2
Possible Cause: Moisture is trapped in the control panel.
Remove the Alde control panel from the vehicle and air in a warm, dry place overnight.DIY Safe
N/A
Alde gas failure
Possible Cause: Out of gas or gas is not igniting.
Check the gas cylinder is full. Try a different gas cylinder, ensuring it is propane gas.DIY Safe
N/A
Alde overheat red fail or overheat blue fail
Bleed the system of air. Check the fluid level in the expansion tank (should be 1cm above Min mark when cool). Check the circulation pump is responding. Wait 15 mins for the fluid to cool down.DIY Safe
N/A
Alde overheat PCB
Possible Cause: Failsafe in boiler has triggered.
Check the fluid level in the expansion tank (should be 1cm above the Min mark when cool). Check the boiler compartment is ventilated, and that the vents are unobstructed.DIY Safe
N/A
Alde connection failure
Possible Cause: Loose connection between Alde control panel and boiler.
Unplug cable at the control panel and boiler, then carefully plug back in. Check there is slack on the cable at the control panel, but not excessive weight from free-hanging/unmanaged cable.DIY Safe
N/A
Alde low battery
Possible Cause: 12V supply to boiler has dropped below 10.5V, possibly causing system brownout.
Automatically clears when 12V supply reaches 11V.DIY Safe
N/A
Aventa air conditioning unit appliance not cooling
Possible Cause: Thawing process in progress or remote control temperature setting reached or too high.
Wait for thawing process to complete or adjust remote control temperature setting.DIY Safe
N/A
Aventa air conditioning unit device not heating
Possible Cause: Thawing process in progress (outside temperature between 4ºC - 7ºC) or outside temperature below 4ºC.
Wait for thawing process or note that device does not operate below 4ºC outside temperature.DIY Safe
N/A
Aventa air conditioning unit cooling/heating inadequately or not at all
Possible Cause: Panels dirty or external air routes soiled/blocked.
Clean panels and clear external air routes.DIY Safe
N/A
Water dripping out of Aventa air conditioning unit air distributor
Possible Cause: Moisture on underside, condensation trap on external unit blocked, seal between appliance and roof not intact, or system at too much of an angle.
Close windows and doors and select high fan level. Clear condensation trap, check seal, or correct vehicle angle.DIY Safe
N/A
Aventa remote control not working or appliance not reacting
Possible Cause: Batteries flat, remote out of range, or remote not paired.
Check and replace batteries in the remote control if necessary. Move into range or pair remote with air conditioning system.DIY Safe
Red LED flashing
Aventa air distributor red LED flashing
Possible Cause: Error in the control system.
Switch the air conditioning system off, wait for a short time and then switch it on again. If the red LED remains lit, contact Truma Service.DIY Check / Tech Fallback
White LED flashing
Aventa air distributor white LED flashing
Possible Cause: Bluetooth pairing not possible.
Delete superfluous Truma apps and repeat pairing.DIY Safe
N/A
Refrigerator does not start
Possible Cause: Refrigerator is not switched on or vehicle is not level.
Switch on the refrigerator, make sure the vehicle is level, or try to start the refrigerator on another power source.DIY Safe
Error code 3
Refrigerator does not work on gas
Possible Cause: Gas bottle is empty, valve of the gas bottle and/or shut-off valves are closed, or refrigerator is not switched on.
Replace the gas bottle, open the valves, switch on the refrigerator, or try to run the refrigerator on another power source.DIY Safe
Operational Fault
Refrigerator does not work on 12V
Possible Cause: Engine is not running or 12V fuse faulty.
Make sure the engine is running, check if the 12V fuse in the fuse box on your vehicle is operational, or try to run the refrigerator on another power source.DIY Safe
Error code 10
Refrigerator does not work on 230V
Possible Cause: Mains are not available.
Check if the mains is available or try to run the refrigerator on another power source.DIY Safe
Error code 11
Refrigerator does not work in Auto
Possible Cause: Sources are not connected.
Connect the sources or try to run the refrigerator on another power source manually.DIY Safe
N/A
Refrigerator has insufficient cooling
Possible Cause: Ventilation openings completely or partially blocked, vehicle not level, selected cooling level too low, fans not switched on, door not properly closed, or too much ice on cooling fins.
Clean or remove blockage, make sure vehicle is level, select higher cooling level, switch on fans, close door, or defrost the refrigerator.DIY Safe
N/A
Burners do not burn or burn unevenly
Possible Cause: Gas bottle is empty as tap is closed, burner caps are not correctly positioned, or burners are wet or clogged.
Change gas bottle and open tap. Allow caps to cool, then re-position them. Dry or clean burners.DIY Safe
N/A
Spark ignition does not spark
Possible Cause: 12V DC battery is discharged, connections are loose, or ignition points are wet or dirty.
Charge battery, secure connections, or dry/clean ignition points.DIY Safe
N/A
Control knobs do not function
Possible Cause: Knobs are mounted incorrectly.
Install knobs correctly.DIY Safe
LO-BAT
Safe lock doesn't close
Possible Cause: Battery is low.
Replace the batteries.DIY Safe
E-CODE
Safe emits three short audible signals
Possible Cause: False code or false master code entered.
Enter the correct code or master code.DIY Safe
HOLD15
Safe emits two short audible signals whenever any button is pressed
Possible Cause: The safe lock is disabled after the wrong code has been entered three times.
Wait for 15 minutes without pressing any buttons, then enter the correct code, or open the door mechanically with the master key.DIY Safe
N/A
TV reception very poor
Possible Cause: Incorrect amplifier gain, incorrect antenna alignment, or wrong polarity.
Check the amplifier gain is set to maximum (rotate clockwise). Check antenna alignment directed at the transmitter. Ensure polarity is correct (horizontal or vertical). Bypass amplifier using Short Hook-Up Test 1 and re-tune TV.DIY Safe

Frequently Asked Questions

Q: How do I calibrate the Watermaster IC water system?

1. Press and hold the calibration button until the green LED starts to flash after 1-3 seconds. 2. Open the cold shower and the pump should start. 3. After approximately 30 seconds, turn off the shower. 4. After approximately 10 seconds, press and hold the calibration button again until the LED turns green and the pump will stop after approximately 10 seconds. 5. The green LED should turn off and blink briefly every 5 seconds indicating the system is calibrated.

Q: How do I adjust the torque settings for caravan wheels?

Tighten all bolts equally in the specified sequence. Torque settings are: Steel wheels 88Nm (65 lbs/ft); Alloy wheels 130Nm (96 lbs/ft). For alloy wheels, first tighten all bolts to 85Nm (63lbs/ft) then go around again in sequence and increase the torque to 130Nm (96lbs/ft). Use correct conical and tapered wheel bolts stamped 10.9.