Technical Specifications

ElectricalSupply voltage: 12V DC, Current consumption: max 5 A with external pump, Fuse rating: 7.5 A automotive fuse integrated in toilet control, Minimum cable cross-section: 1.5 mm², Max external water pump rated capacity: 60 W
Gas Or PressureSolenoid valve water operating pressure: max 6 bar (87 PSI)
Capacities DimensionsCassette tank capacity: 19 l (5.02 US gal), Optional freshwater tank capacity: 7 l (1.85 US gal), Required pump output: >= 7 l/min (1.85 US gal/min), Operating temperature range: 0 °C to +50 °C (+32 °F to +122 °F)

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
N/A
Solenoid valve damaged or leaking
Possible Cause: Water pressure exceeding the 6 bar (87 PSI) threshold
Ensure the water system pressure regulator does not exceed 6 bar and replace the solenoid valve.DIY Safe
N/A
Water pump fails to run or electrical failure
Possible Cause: Blown internal 7.5 A fuse or incorrect wiring/parallel connection