Official technical documentation and workshop diagnostics for HiPro.

Technical Specifications

ElectricalInput Voltage: 220 V – 240 V AC, 50/60 Hz (Absorption A series & Compressor C series); 100 V – 240 V AC, 50/60 Hz (Thermoelectric N series). Rated input power: 60 W – 70 W (Absorption A series), 45 W (Compressor C series), 55 W (Thermoelectric N series). Light source energy efficiency class: F.
Gas Or PressureRefrigerants: R717 (Ammonia for Absorption series), R600a (Compressor & Thermoelectric series). Absorber unit is under high pressure.
Capacities DimensionsTotal Volume: 26 L (A30, N30), 33 L (A40, C40, N40), 49 L (C60). Climate Class: N (16°C – 32°C), T (16°C – 43°C). Noise Emission: 0 dB(A) for A and N series; 33 dB(A) for C40; 38 dB(A) for C60.

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
N/A
Minibar is not cooling. Indicator LED is off.
Possible Cause: Power plug not plugged in, no voltage at socket, defective electronics fuse, defective heating cartridge (absorption models), or defective electronics/temperature sensors/cooling unit.
Insert power plug, check circuit breaker, and have authorized service agent replace fuse, heating cartridge, NTC sensor, electronics, or cooling unit/minibar as needed.DIY Check / Tech Fallback
N/A
Minibar is not cooling. Indicator LED flashes orange 1x.
Possible Cause: NTC sensor is defective.
Contact an authorized service agent to replace the NTC sensor.Professional Intervention Required
N/A
Minibar is not cooling. Indicator LED flashes orange 3x.
Possible Cause: Heating cartridge is defective (absorption models only).
Contact an authorized service agent to install a new heating cartridge.Professional Intervention Required
N/A
Minibar is not cooling. Indicator LED flashes orange 5x.
Possible Cause: CPC (cooling performance control) error.
Temporarily disconnect minibar from power supply to reset error. Count flashes post-reset (1x = NTC error, 3x = heating cartridge error, no flashing = error reset). Contact service agent if 1x or 3x flashes persist.DIY Check / Tech Fallback
N/A
Minibar is not cooling. Interior light flashes continuously.
Possible Cause: Error during self-test of the cooling unit (absorption models).
Check cooling unit for leaks, check ventilation grille, and wait 24 hours for device to restart. If it does not restart, contact an authorized service agent.DIY Check / Tech Fallback
N/A
Poor cooling performance.
Possible Cause: Cooling unit not sufficiently ventilated, direct sunlight exposure, door not sealed tightly, recently filled with goods, or input voltage too high/low (absorption models).
Provide sufficient ventilation, remove from direct sunlight, check/replace door seal, re-check cooling after 5 to 6 hours, and check input voltage.DIY Safe
N/A
Interior lighting is not working.
Possible Cause: Defective interior lighting or infrared door sensor surface covered (e.g., by condensation).
Clean the surface of the infrared door sensor, or contact an authorized service agent to replace the interior lighting.DIY Check / Tech Fallback