Dometic • Wine Cabinet

Dometic MaCave

Official technical documentation and workshop diagnostics for Dometic MaCave.

Technical Specifications

Electrical220 – 240 V / 50 Hz, Circuit protection: 15 A, Power consumption: 139 kWh/year (S16FG), 145 kWh/year (S40FGD), 225 kWh/year (S117FG)
Gas Or PressureNot applicable (Compressor-based refrigeration system)
Capacities DimensionsCapacities: S16FG (16-19 Bordeaux bottles, 29 kg), S40FGD (40-52 Bordeaux bottles, 50 kg), S117FG (117-141 Bordeaux bottles, 92 kg). Climate class: ST (+16 °C to +38 °C / +61 °F to +100 °F). Temperature range: +5 °C to +22 °C (+41 °F to +72 °F), Beverage mode: +2 °C to +6 °C (+36 °F to +43 °F).

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
N/A
Appliance does not work
Possible Cause: The appliance is not connected to a power supply or is switched off, circuit breaker or fuse has blown
Connect the appliance, switch it on, reset the circuit breaker or replace the fuse.DIY Safe
N/A
The appliance is not cold enough
Possible Cause: Temperature is not set properly, ambient temperature requires a higher setting, door opened frequently or not closed properly, door seal not hermetically sealed
Check set temperature, adjust for ambient conditions, close door properly, check/clean or replace door seal.DIY Safe
N/A
Appliance switches itself on and off
Possible Cause: Room temperature higher than average, cabinet recently replenished with new bottles, door opened frequently or not sealed
Move appliance to a cooler place, allow appliance time to reach set temperature, minimize door openings, ensure proper door seal.DIY Safe
N/A
The light does not work
Possible Cause: Not connected, fuse blown, light switched off on control panel
Connect appliance, replace/reset fuse, switch on light via control panel.DIY Safe
N/A
The appliance vibrates or makes a lot of noise
Possible Cause: Appliance is not properly level; normal refrigerant flow or wall expansion/contraction noises
Level out the appliance using the adjustable feet. Refrigerant and cracking noises are normal operating sounds.DIY Safe
N/A
The door does not close properly
Possible Cause: Appliance not level, door hinge changed incorrectly, dirty door seal, shelves not fitted correctly
Level appliance, check and reassemble door hinge correctly, clean door seal, check and refit shelves correctly.DIY Safe
N/A
LED display shows E1, E2 or E7
Possible Cause: Temperature sensor for air temperature inside appliance shows an error
Contact an authorized repair centre.Professional Intervention Required
N/A
Appliance is not cold enough
Possible Cause: Temperature is not set properly / Ambient temperature requires higher setting / Frequent door opening / Door not closed properly / Door seal not hermetically sealed
Check the set temperature / Set a higher temperature / Do not open the door more often than necessary / Close door properly / Check door seal and clean or replaceDIY Safe
N/A
The appliance vibrates
Possible Cause: Appliance is not properly leveled
Level the appliance with the adjustable feetDIY Safe
N/A
The appliance seems to make a lot of noise
Possible Cause: Normal refrigerant flow noise or contraction/expansion of inner walls due to temperature fluctuations / Improper leveling
Refrigerant and wall noises are normal. For leveling issues, level the appliance with the adjustable feetDIY Safe
N/A
LED indicates E1, E2 or E7
Possible Cause: Temperature sensor for the fan inside the appliance shows an error
This can only be repaired by an authorised repair centre.Professional Intervention Required