Dometic • General Equipment

Dometic MSI912, MSI924, MSI1312, MSI1324, MSI1812, MSI1824, MSI1812T, MSI1812TOE, MSI1824T

Official technical documentation and workshop diagnostics for SinePower.

Technical Specifications

Operating Voltage12V DC / 24V DC
Power ConsumptionIdle current consumption: 1.0A - 2.1A; Standby: 0.3A - 0.5A
Fuse Ratings75A - 228A cable fuse depending on model; 10A 230V input fuse (T models)
Dimensions CutoutSee manual technical drawings for exact dimensions

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
N/A
Input Level LED flashes quickly (red)
Possible Cause: Input voltage is too high
Check the input voltage and reduce it. If the issue remains unresolved, contact an authorised service agent.DIY Check / Tech Fallback
N/A
Input Level LED flashes slowly (red)
Possible Cause: Input voltage is too low
The battery needs recharging. Check the cables and connections. If the issue remains unresolved, contact an authorised service agent.DIY Check / Tech Fallback
N/A
Input Level LED flashes occasionally
Possible Cause: Overheating
Switch off the inverter and the load. Wait about 5 to 10 minutes. The inverter is being reset. Then switch the inverter back on without the load. Reduce the load and make sure the inverter has better ventilation. Then switch the load back on. If the issue remains unresolved, contact an authorised service agent.DIY Check / Tech Fallback
N/A
Load Status LED is constantly lit (red)
Possible Cause: Short circuit or reversed polarity, or excessive load
Switch off the inverter and remove the load. Then switch the inverter back on without the load. If no excessive load is now shown, then there is a short circuit in the load or the total load was higher than the power specified on the data sheet. For MSI1812T, MSI1812TOE and MSI1824T: The fuse in the device must be pressed in again by hand after it is triggered. Check the cables and connections. If repairs are necessary, have repairs carried out by a specialist.DIY Check / Tech Fallback