Technical Specifications

ElectricalBattery: Maintenance-free sealed lead-gel, 18 Ah, 12 V DC. Starter current: Max. 400 A (short-term). Outputs: 12 V DC, max. 10 A. Mains charger input: 230 V ~ 50 Hz AC. Mains charger output: 12 V, 1000 mA DC. 12 V charging cable fuse: 16 A.
Gas Or PressureNot applicable
Capacities DimensionsWeight: 8.5 kg. Dimensions: 288 x 250 x 201 mm (H x W x D). Charging time (230V mains charger): approx. 24-48 hours.

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
N/A
Reverse polarity detected during connection (Wrong polarity)
Possible Cause: Red and black clamps connected to incorrect battery terminals
Disconnect clamps immediately. Ensure red clamp connects to positive (+) terminal and black clamp connects to negative (-) terminal.DIY Safe
N/A
Automatic fuse trips during 12 V appliance operation (Overload)
Possible Cause: Connected 12 V appliance exceeds maximum current draw of 10 A
Switch off 12 V appliance, unplug from cigarette lighter socket, wait approximately 2 minutes for the overload fuse to automatically reset, then reconnect keeping load under 10 A.DIY Safe
N/A
Complete discharge warning alarm sounds (Low level discharge)
Possible Cause: Battery voltage has dropped too low (deep discharge risk)
Recharge the PowerPack immediately to prevent permanent battery damage.DIY Safe
N/A
Safety relay fails to switch when attempting jumpstart
Possible Cause: Vehicle battery residual voltage is too low (below the required threshold)
Ensure the vehicle battery has a minimum residual voltage of approximately 2 V to activate the internal safety relay.DIY Safe