Technical Specifications

Electrical12 V DC generator power supply. Max length 2m when using a 2 x 0.5 mm2 cable. Terminal board identified with "+12 V -"; Red terminal is positive pole, black terminal is negative pole. Never connect to 230V AC mains voltage.
Gas Or PressureCategories: I3B/P(30) at 30 mbar Butane (G30) / Propane (G31); I3+ at 28-30 mbar Butane (G30) and 37 mbar Propane (G31). Auxiliary burner injector: 0.50 mm (Stamped 50), or 0.45 mm for mod. PI7903T - PI7923T (Stapped 45). Semi-rapid burner injector: 0.67 mm (Stamped 67), or 0.64 mm for mod. HBH1303ILG/IRG (Stamped 64). Rapid burner injector: 0.75 mm (Stamped 75).
Capacities DimensionsBuilt-in Class 3 appliance. Minimum wall distances: A/B from burner edge to side/rear walls = 135 mm; C from top of burners to overhead units/shelves = 500 mm; D from bottom of burner to underside = 30 mm. Pan diameters: Auxiliary (47 mm) = 6 to 16 cm; Semi-rapid (62 mm) = 16 to 22 cm (10 to 16 cm for HBH1303ILG/IRG); Rapid (77 mm) = 16 to 22 cm.

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
N/A
Burner does not ignite immediately
Possible Cause: Air in gas lines, closed gas cylinder valve, or incorrect ignition procedure
Turn knob to small flame position, perform manual ignition, and check that there is sufficient gas in the cylinder.DIY Safe
N/A
Appliance completely fails to function / no gas supply
Possible Cause: Main gas supply shut off, empty gas cylinder, or component failure
Close gas inlet tap, check gas cylinder level, and contact authorized dealer/service engineer.DIY Check / Tech Fallback
N/A
Gas leak detected (smell of gas)
Possible Cause: Loose fittings, damaged flexible hose, or open valve
Immediately open windows, evacuate vehicle, extinguish all open flames, do not touch electrical switches, shut off gas cylinder valve, and contact an authorized technician.Professional Intervention Required