Truma • Heating & Water

Truma BG 10 BGE 10

Official technical documentation and workshop diagnostics for Boiler BG 10 / BGE 10.

Technical Specifications

Operating Voltage12V DC / 230V AC
Power Consumption12V: Ignition 0.16A, Heating 0.12A, Standby 0.05A; 230V: 850W (3.7A) / 1300W (5.7A)
Gas Or PressureLiquid gas (propane / butane) at 30 mbar
Fuse Ratings1.6A slow-acting fine wire fuse (EN 60127-2-3)
Dimensions CutoutCowl cutout: see technical drawings, max pump pressure 2.8 bar, system pressure max 4.5 bar

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
N/A
Boiler does not operate after switching on (Gas mode)
Possible Cause: No 12V power supply
Check the battery voltage (minimum operating voltage 10.5V). Check the boiler fuse on the electronic control unit. If the issue remains unresolved, contact an authorized service agent.DIY Check / Tech Fallback
N/A
Boiler does not operate after switching on (Gas mode)
Possible Cause: Window open above cowl
Close the window above the cowl.DIY Safe
N/A
After switching on, boiler does not operate and red LED comes on after about 30 seconds
Possible Cause: Cowl cover is fitted
Remove the cowl cover and/or check for soiling and remove if necessary.DIY Safe
N/A
After switching on, boiler does not operate and red LED comes on after about 30 seconds
Possible Cause: No gas supply or incorrect gas pressure
Check gas valves and gas cylinder.DIY Safe
N/A
After switching on, boiler does not operate and red LED comes on after about 30 seconds
Possible Cause: Air in gas supply
To clear the fault and bleed off air, switch the appliance off, wait for 5 minutes and switch it on again.DIY Safe
N/A
After a long period of operation, boiler switches to 'Fault' and red LED comes on
Possible Cause: Overtemperature sensor has activated
Check the water content, topping up if necessary by closing the drain valve. To clear the fault, switch the appliance off, wait for 5 minutes and switch it on again. If the issue persists, contact an authorized service agent.DIY Check / Tech Fallback
N/A
Boiler does not operate after switching on (Electrical mode BGE 10)
Possible Cause: No 230V power supply
Connect the vehicle to the local central power supply and/or check the residual current protective device.DIY Safe
N/A
Boiler does not operate after switching on (Electrical mode BGE 10)
Possible Cause: Overtemperature sensor has activated
Check the water content, topping up if necessary by closing the drain valve. The electric heating element is fitted with an overtemperature sensor; switch off at the control panel, wait for 10 minutes, then switch on again. If the issue remains unresolved, contact an authorized service agent.DIY Check / Tech Fallback
N/A
Heats up too slowly with switch set to 850W (Electrical mode BGE 10)
Possible Cause: Insufficient heating output selected for conditions
Contact Truma Service or an authorized workshop.Professional Intervention Required
N/A
Water dripping from drain valve
Possible Cause: Water pressure too high
Check water pressure (max. 2.8 bar). When connecting to a central water supply, a pressure reducer must be used.DIY Safe
N/A
Warm water coming out of cold water tap
Possible Cause: Hot water flowing back into cold water supply
Fit a non-return valve to the cold water supply in accordance with the installation instructions.DIY Safe