Truma C 3402 / C 6002
Official technical documentation and workshop diagnostics for Trumatic C.
Technical Specifications
Operating Voltage12V DC / 230V AC
Power ConsumptionHeater + water heater: C 4002: 0.2 – 5.6 A (average power consumption 1.3 A), C 6002: 0.2 – 5.6 A (average power consumption 1.4 A); Heating up of water heater: 0.4 A; Stand-by: 0.001 A; Electrical safety/drain valve: 0.035 A
Gas Or PressureLiquid gas (propane/butane), 30 mbar
Fuse RatingsDevice fuse: 6.3 AT (slow), Control panel fuse (F3): 1.6 AT (slow)
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|
N/A | No control lamp lights up when the system is switched on (winter and summer operation). Possible Cause: Device fuse or vehicle fuse defective, open window above cowl (window switch), or low battery voltage. | Charge battery voltage (12 V), check all electrical plug connections and fuses, and close the window. | DIY Safe |
N/A | The green indicator lamp comes on when the equipment is switched on (using the ZUC timer), but the heater is not operating. Possible Cause: Open window above cowl (window switch). | Close the window. | DIY Safe |
N/A | The red monitor lamp flashes after the heating system has been switched on. Possible Cause: Battery voltage is too low (< 10.5 V). | Charge the battery. | DIY Safe |
N/A | About 30 seconds after the heating has been switched on, the red monitor lamp lights up and remains steady. Possible Cause: Gas cylinder or quick-closure valve in the gas line is closed, or air feed interrupted. | Check gas feed, check cowl for possible coverage, and if being used on boats, open the deck cowl. | DIY Safe |
N/A | Heating switches to Fault mode after an extended period of operation. Possible Cause: Hot-air outlets blocked, gas pressure regulator iced up, or butane content in the gas cylinder too high. | Check individual outlet apertures, use de-icing system controller (EisEx), and use propane (at temperatures below 10°C in particular, butane is unsuitable for heating purposes). | DIY Safe |
N/A | No control lamp lights up when the 230 V electrical operation system is switched on. Possible Cause: No supply voltage. | Check 230 V supply voltage and fuses. | DIY Safe |
N/A | When the heating system is switched off, the electrical safety/drain valve opens. Possible Cause: Outside temperature below 4°C or no 12 V power supply at the drain valve. | Switch the heating on (at temperatures of about 4°C and below the drain valve will open automatically). Check 12 V supply voltage and fuses. | DIY Safe |
N/A | The electrical safety/drain valve will no longer close, or water is dripping from the electrical safety/drain valve. Possible Cause: Outside temperature below 8°C, no 12 V power supply at the drain valve, or water pressure too high. | Switch the heating on (without heating operation, the drain valve will not close again until temperatures above 8°C have been reached), check 12 V supply voltage and fuses, and check pump pressure (max. 2.8 bar). If connected to a central water supply, use a pressure reducer to prevent pressures higher than 2.8 bar entering the boiler. If the issue remains unresolved, contact an authorized service agent. | DIY Check / Tech Fallback |