Truma • Heating & Water

Truma CP plus VarioHeat control panel

Official technical documentation and workshop diagnostics for CP plus VarioHeat.

Technical Specifications

Operating Voltage8 V - 16.5 V DC
Power Consumptionmax. 65 mA (100% background lighting), 6.5 mA - 10 mA (stand-by), max. 3 mA (Off)
Dimensions Cutout92 x 103 x 40 mm

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
E 2 H
Flame not recognised / Heater fault
Possible Cause: Gas cylinder empty
Replace gas cylinderDIY Safe
E 2 H
Flame not recognised / Heater fault
Possible Cause: Gas cylinder or quick-acting valve in the gas supply line closed
Check gas supply and open valvesDIY Safe
E 2 H
Flame not recognised / Heater fault
Possible Cause: Gas pressure regulation system iced up
Use EisEx regulator heaterDIY Safe
E 2 H
Flame not recognised / Heater fault
Possible Cause: Butane content in the gas cylinder too high
Use propane (butane is unsuitable for heating, particularly at temperatures below 10 °C)DIY Safe
E 2 H
Flame not recognised / Heater fault
Possible Cause: Combustion air infeed or exhaust outlet is sealed
Inspect openings for obstructions (slush, ice, leaves, etc.) and remove any obstructionsDIY Safe
W 25 H
Overvoltage warning
Possible Cause: Overvoltage > 16.4 V
Check the battery voltage and voltage sources such as the chargerDIY Safe
W 26 H
Low voltage warning
Possible Cause: Low voltage, battery voltage too low < 10 V
Charge battery and replace old battery if necessaryDIY Safe
W 27 H
Air flow warning
Possible Cause: Warm air outlets blocked, circulated air intake blocked, or end outlets EN closed
Remove blockage and open end outlets ENDIY Safe
W 28 H
Window switch warning
Possible Cause: Window above cowl open (window switch)
Close windowsDIY Safe
W 29 H
Risk of low voltage warning
Possible Cause: Risk of low voltage, battery voltage too low < 10.4 V
Charge batteryDIY Safe
W 255 H
Power supply or connection warning
Possible Cause: Heater has no 12 V power supply or no connection between heater and control panel
Ensure 12 V power supply, connect heater and control panel. If the issue remains unresolved, contact an authorised service agent.DIY Check / Tech Fallback
E 8 A
Air conditioning system fault
Possible Cause: IR receiver unplugged or cable broken
Check the connection of the IR receiverDIY Safe
E 17 A
Air conditioning system fault
Possible Cause: Voltage drop at 230 V power supply
Check 230 V power supplyDIY Safe
W 8 A
Air conditioning system warning
Possible Cause: IR receiver unplugged or cable broken
Check the connection of the IR receiverDIY Safe
W 17 A
Air conditioning system warning
Possible Cause: Voltage drop at 230 V power supply
Check 230 V power supplyDIY Safe
W 101 E
E-Kit overvoltage warning
Possible Cause: Overvoltage > 16.1 V
Check the battery voltage and voltage sources, such as the chargerDIY Safe
W 102 E
E-Kit low voltage warning
Possible Cause: Low voltage, battery voltage too low < 10.4 V
Charge battery and replace old battery if necessaryDIY Safe
W 103 E
E-Kit air flow warning
Possible Cause: Warm air outlets blocked or circulated air intake blocked
Check the individual outlet openings and remove the circulated air intake blockageDIY Safe
W 104 E
E-Kit voltage warning
Possible Cause: No 230 V operating voltage or 230 V fuse defective
Restore 230 V operating voltage or replace 230 V fuseDIY Safe
W 255 E
E-Kit power supply or connection warning
Possible Cause: Truma E-Kit has no 12 V power supply or no connection between Truma E-Kit and control panel
Ensure 12 V power supply, connect heater and control panel. If the issue remains unresolved, contact an authorised service agent.DIY Check / Tech Fallback