Truma • Heating & Water

Truma GasCheck

Official technical documentation and workshop diagnostics for Industrial GasCheck.

Technical Specifications

Operating Voltage9V DC
Gas Or PressurePropane / Butane LPG
Dimensions Cutout138 x 35 x 30 mm

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
N/A
Incorrect measurement
Possible Cause: Dirty measuring head, dust particles from aluminium cylinders, dirty or rusty gas cylinders, invisible patches of rust inside the cylinder, very thick paint, stickers, condensation, or dented/scratched gas cylinders.
Clean the measuring head with a damp cloth, clean the gas cylinder at the measuring point, or measure at a different place on the cylinder.DIY Safe
N/A
LED flashes red or green with low voltage warning (measurement still possible)
Possible Cause: Battery is low.
Replace the battery with a new E block 9V (Type 6 LR 61, 6 F 22) battery, ensuring correct polarity.DIY Safe
N/A
Red status LED flashes and the appliance beeps 3 times (no measurement possible)
Possible Cause: Battery is flat.
Replace the flat battery with a new E block 9V (Type 6 LR 61, 6 F 22) battery, ensuring correct polarity.DIY Safe