Truma LevelControl
Official technical documentation and workshop diagnostics for LevelControl.
Technical Specifications
Operating Voltage3V DC / 2 x 1.5 V batteries (alkaline, LR03, AAA)
Power ConsumptionOperation max. 70 mA, Quiescent current consumption 0.001 mA
Gas Or PressureLiquid gas (propane / butane)
Dimensions Cutout185 x 73 x 16 mm
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|
N/A | No coupling possible between Truma LevelControl and Truma iNet Box. Possible Cause: Distance too great | Reduce the distance between the units. | DIY Safe |
N/A | No coupling possible between Truma LevelControl and Truma iNet Box. Possible Cause: Truma LevelControl is shielded | Put Truma LevelControl next to Truma iNet Box, use supporting feet for gas cylinder. | DIY Safe |
N/A | No coupling possible between Truma LevelControl and Truma iNet Box. Possible Cause: Batteries are flat or incorrectly inserted | Change battery or insert them with the correct polarity. | DIY Safe |
N/A | No coupling possible between Truma LevelControl and Truma iNet Box. Possible Cause: Button (5) not pressed (status LED (2) not flashing) | Press button (5). | DIY Safe |
N/A | Status LED (2) not flashing when button (5) is pressed. Possible Cause: Batteries are flat or incorrectly inserted | Change battery or insert them with the correct polarity. | DIY Safe |
N/A | Truma LevelControl does not stick to the gas cylinder. Possible Cause: Aluminium gas cylinder used | Use clamping sheet available as accessory. | DIY Safe |
N/A | Truma LevelControl does not fit under gas cylinder. Possible Cause: Gas cylinder base not deep enough | Use supporting feet for gas cylinder. | DIY Safe |
N/A | Truma LevelControl does not fit under gas cylinder. Possible Cause: Gas cylinder not suitable | Replace gas cylinder with a suitable gas cylinder type as seen in the Truma App. | DIY Safe |
N/A | Measurement uncertain Possible Cause: Measurement not yet completed | Wait for at least five minutes and check measured value again. | DIY Safe |
N/A | Measurement uncertain Possible Cause: Fill level too low | Note that the measured value is displayed greyed out below approx. 10% of the total fill level. | DIY Safe |
N/A | Measurement uncertain Possible Cause: Gas cylinder damaged or dirty | Replace or clean gas cylinder. | DIY Safe |
N/A | Measurement uncertain Possible Cause: Truma LevelControl fitted incorrectly | Install Truma LevelControl as per instructions. | DIY Safe |
N/A | Gas cylinder fill level is not updated. Possible Cause: Gas cylinder empty | Replace gas cylinder. | DIY Safe |
N/A | Gas cylinder fill level is not updated. Possible Cause: Truma LevelControl not configured | Configure Truma LevelControl in Truma App. | DIY Safe |
N/A | Gas cylinder fill level is not updated. Possible Cause: Poor acoustic coupling | Place Truma LevelControl elsewhere on the cylinder base. | DIY Safe |
N/A | Gas cylinder fill level is not updated. Possible Cause: Gas cylinder or coupling pad dirty (e.g. rust, ice) | Clean the gas cylinder or coupling pad. | DIY Safe |
N/A | Gas cylinder fill level is not updated. Possible Cause: Coupling pad damaged or missing | Contact Truma Service for replacement. | Professional Intervention Required |
N/A | Gas cylinder fill level is not updated. Possible Cause: Gas cylinder in poor condition or unsuitable | Replace gas cylinder. | DIY Safe |
N/A | Gas cylinder fill level is not updated. Possible Cause: Truma LevelControl not installed correctly on cylinder | Install as per the instructions. | DIY Safe |
N/A | Gas cylinder fill level is not updated. Possible Cause: Button (5) not pressed after gas cylinder change | Press button (5) or reconfigure Truma LevelControl in the Truma App. | DIY Safe |
N/A | No Truma LevelControl is displayed in the Truma App Possible Cause: No connection possible to the Truma LevelControl | Reduce distance between Truma LevelControl and Truma iNet Box or place gas cylinder on supporting feet. If these actions do not remedy the problem, contact an authorized service agent. | DIY Check / Tech Fallback |
