Truma • Water Heaters

Truma Therme (TT2) Water Heater

The Truma Therme is a hot water heater designed for caravans, utilizing warm air from the heating system or a 230V electric heating element to heat up to 5 liters of water. It operates in a pressure-free system and features a thermostat-controlled heating limit of 65 °C.

Technical Specifications

Power Consumption 230v1.3 A (300 W)
Water Capacity Litres5 litre
Weight Kg2 kg (complete with drain and vent valves, excluding contents)

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
Device is not heating
No operating voltage
Restore power supplyDIY Safe
Heating not working
No operating voltage.
Restore the power supply.DIY Safe
Operational Fault
Heater is calcified
Descale the water system (see maintenance)DIY Safe
Operational Fault
No operating voltage (Geen bedrijfsspanning)
Restore power supply (Stroomvoorziening herstellen)DIY Safe
Operational Fault
Scale buildup on the heating element
Descale water installationDIY Safe
Operational Fault
Heating element furred.
Descale water system (see maintenance).DIY Safe
Operational Fault
Heating element bent
Descale water system (refer to "Maintenance")DIY Safe
Operational Fault
Scaling on the heating element.
Descale the water system according to maintenance instructions.DIY Safe
Operational Fault
Scaling on the heating element.
Descale the water system (see Maintenance).DIY Safe

Frequently Asked Questions

Q: How do I drain the Truma Therme for winter storage?

Disconnect the water pump, open water valves in the kitchen/bathroom, and open the drain and vent valves completely to let the water empty out.

Q: Can the Truma Therme be operated without water?

No, the Therme must never be operated with electricity without water.

Q: What is the maximum operating pressure allowed for the Therme?

The Therme is designed for pressure-free operation. When connecting to a central water supply or stronger pumps, a pressure reducer preventing pressure from exceeding 1.2 bar must be used alongside a safety/drain valve.

Q: How should the Therme be filled with water?

Close the drain and vent valves completely by turning them, set the hot water tap to 'warm' (or the control knob to the red symbol in pre-mixing systems), and leave the tap open until all air is expelled from the Therme and water flows out of the taps.

Q: What should I do if there is a risk of frost?

Disconnect the power supply to the water pump, drain the water tank or remove the pump from the tank, open all water taps to 'warm', and open the drain and vent valves completely to empty the Therme entirely.

Q: What is the maximum operating pressure for the Therme?

The maximum operating pressure is 1.2 bar; only pumps without a non-return valve may be used, and a pressure regulator must be used in the case of central water supplies or stronger pumps.