Truma • Heating & Water

Truma VarioHeat

Official technical documentation and workshop diagnostics for VarioHeat.

Technical Specifications

Operating Voltage12V DC
Power ConsumptionTruma VarioHeat eco: 0.65 / 2.75 A; Truma VarioHeat comfort: 0.65 / 2.75 / 5.4 A
Gas Or PressureLiquefied gas (propane / butane) at 30 mbar
Fuse RatingsAppliance fuse (F1): 10 AF – quick – (EN 60127-2-3)
Dimensions Cutout380 x 248 x 123 mm

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
N/A
LEDs do not light up, appliance is switched on, operating voltage present
Possible Cause: Automatic restart is blocked, e.g. after a power failure
Reset (fault reset) by switching off, wait for 5 seconds and then switch on againDIY Safe
N/A
No LED illuminates after switching on
Possible Cause: No operating voltage
Check 12 V battery voltage, charge battery if necessary, and check plug connectionsDIY Safe
N/A
No LED illuminates after switching on
Possible Cause: Appliance fuse or vehicle fuse defective
Check fuse of appliance or vehicle and replace if necessaryDIY Safe
N/A
The green LED lights up after switching on, but the heater does not operate
Possible Cause: The temperature set on the control panel is lower than the room temperature
Select a higher room temperature on the control panelDIY Safe
Operational Fault
After operating for a longer period of time, the heater switches to fault
Possible Cause: Gas cylinder or quick-acting valve in the gas supply line closed
Check gas supply and open valvesDIY Safe
Operational Fault
After operating for a longer period of time, the heater switches to fault
Possible Cause: Gas cylinder empty
Replace the gas cylinderDIY Safe
Operational Fault
After operating for a longer period of time, the heater switches to fault
Possible Cause: Gas pressure regulation system iced up
Use EisEx regulator heaterDIY Safe
Operational Fault
After operating for a longer period of time, the heater switches to fault
Possible Cause: Butane content in the gas cylinder too high
Use propane (butane is unsuitable for heating, particularly at temperatures below 10 °C)DIY Safe
Operational Fault
After operating for a longer period of time, the heater switches to fault
Possible Cause: Combustion air infeed or exhaust outlet is sealed
Inspect openings for obstructions (slush, ice, leaves, etc.) and remove any obstructionsDIY Safe
Operational Fault
Heater fault
Possible Cause: Heater internal fault
Contact an authorised service agentProfessional Intervention Required
Operational Fault
After the heater is switched on, the green LED is lit and the red LED flashes 3 x
Possible Cause: Risk of low voltage, battery voltage too low < 10.4 V
Charge batteryDIY Safe
Operational Fault
After the heater is switched on, the green LED is lit and the red LED flashes 3 x
Possible Cause: Low voltage, battery voltage too low < 10 V
Charge battery and replace old battery if necessaryDIY Safe
Operational Fault
After the heater is switched on, the green LED is lit and the red LED flashes 3 x
Possible Cause: Overvoltage > 16.4 V
Check the battery voltage and voltage sources such as the chargerDIY Safe
Operational Fault
Open window above cowl
Possible Cause: Window switch triggered by open window near cowl
Close windowsDIY Safe
Operational Fault
Air flow obstruction
Possible Cause: Warm air outlets or circulated air intake blocked
Remove blockageDIY Safe
Operational Fault
Motor wear limit reached
Possible Cause: Motor wear limit will be reached soon
Contact an authorised service agentProfessional Intervention Required